UCS 5108 power redundancy lost

Well, another day – another UCS error. Out of the blue, one of our chassis started displaying that one PSU had failed, however the UCS was showing no PSU had failed *shrug*

Well, as it turns out – this is yet another known bug in 2.0.2(r). You’ll either have to unplug and plug all the power cables (that’s four) in a maintainance window – or simply change the Equipment Power Policy (found in the Root of your UCS, tab Policy)

from “N+1” to “Non Redundant”; wait a minute or two till the error is “fixed” and then change it back to “N+1”. Problem solved for now … 😀

2 thoughts to “UCS 5108 power redundancy lost”

    1. Well, according to the Release Notes of 2.2(2d), this should be fixed… I haven’t tested it though.

Leave a Reply

Your email address will not be published. Required fields are marked *

I accept that my given data and my IP address is sent to a server in the USA only for the purpose of spam prevention through the Akismet program.More information on Akismet and GDPR.